USER MANUAL FOR COMFLEX-6Q00 5W 
 
ENU STATUS: 1-0-1 
Copyright - refer to title page 
Page 37 
 
 
 
 
4.2 
 LED INDICATORS 
Diagnostic LEDs are located on the MU front panel and RU bottorm panel; each indicates the status of a 
particular function: 
 
Table 9: MU LED Indications 
LED Indicator 
Normal Status 
Indication 
PWR 
Steady green 
Power indicator. If LED is off, it indicates the system 
has no power.  
RUN 
Flashing green 
(1 time/sec) 
MU operation indicator. After initialization (1~2 
minutes), the LED should flash at once per sec. 
(When upgrade firmware, LED will flash rapidly)  
ALM 
OFF 
Alarm indicator. If LED is RED, there is an alarm. 
OP 
Steady green 
Located on Fiber Optical Unit (FOU), it is an 
indicator for receive optical power. If LED is off, it 
indicates the receiving optical power is less than -
10dBm. 
 
Table 10: RU LED Indications 
LED Indicator 
Normal Status 
Indication 
PWR 
Steady green 
Power indicator. If LED is off, it indicates the system 
has no power. 
RUN 
Flashing green 
(1 time/sec) 
RU operation indicator. After initialization (1~2 
minutes), the LED will flash once per sec. (When 
upgrade firmware, LED will flash rapidly) 
ALM 
OFF 
Alarm indicator. If LED is RED, there is an alarm. 
OP 
Steady green 
Located on Fiber Optical Unit (FOU), it is an 
indicator of Receiving optical power. If LED is off, it 
indicates the receiving optical power is less than -
10dBm. 
 
 
4.3 
DIGITAL DISPLAY INDICATORS 
4.3.1  DIGITAL DISPLAY ON RFU 
The digital display tube on RFU shows the DL input power. The range of DL input power shown on the 
display tube is from -19 to 33 (dBm), when DL input power is lower than -19dBm, it will show L, when DL 
input power is higher than 33, it will display H.  
 
 
Figure 35: RFU Digital Display