3.3 
INSTALLATION PROCEDURES 
3.3.1 GOODS INWARDS INSPECTION 
ComFlex was factory tested, inspected, packed, and delivered to the carrier with utmost care. Do not 
accept shipment from carrier which shows damage or shortage until the carrier
’s agent endorses a 
statement of the irregularity on the face of the carrier
’s receipt. Without documentary evidence, a claim 
cannot be processed. 
 
Open and check each package against the packing list. For any shortage, contact Comba Telecom 
Systems. Do not remove items from packing materials until installation.  
 
 
3.3.2 TOOLS 
See Appendix A for a full list of tools required for installation and maintenance. 
 
 
3.3.3 PREPARATION 
Optical Fiber: 
 
 
Fiber optic cables require proper handling. Do not stretch, puncture, or crush the fiber cable(s) with 
staples, heavy equipment, doors, etc. 
 
 
Always maintain the minimum bending radius specified by the cable manufacturer. The minimum 
bend radius is usually 10 times the cable
’s outer diameter. In the case of single optical fiber that is not 
in a cable, the minimum bending radius to be observed is 3cm. 
(1.2”)  
 
 
3.3.4 MU ASSEMBLING  
ComFlex Master Unit consists of 4 parts: Chassis, RFU, FOU and PSU. All the units are packed 
separately. Follow the steps below to assemble. 
 
Figure 5: ComFlex Master Unit