Comba Telecom Ltd. HRU-4300 Manual De Usuario

Descargar
Página de 66
USER MANUAL FOR COMFLEX-4300 
 
ENU STATUS : 1-0-0 
Copyright - refer to title page 
Page 57 
 
 
 
 
  Tip of MU calibration finish will show up on the left of the page, and calibration results will 
show in the table. 
  NOTE
: Each RFU needs to be calibrated; click “More” at last step of process to calibrate next 
RFU. 
 
 
Figure 67: Commissioning Procedure 
– MU Calibration 
 
 
Figure 68: Commissioning Procedure 
– MU Calibration Finish 
 
NOTE1:  Calibration  is  to  adjust  MU  and  RU  gain  to  assure  that  make  sure  system  gain  is  20dB,  if  the 
band have been calibrated, users can click 
 to skip the process; if the band never been calibrated, 
users click 
 in the step of MU Calibration and RU Calibration, software can still procede to the next 
step of MU and RU setup, but the system gain will be a little deviation with 20dB, so the final output power 
will be not same with the target DL output power.  
 
NOTE2
: If there are more than one same band access to MU, then each access need to be calibrated in 
MU  Calibration  step,  while  in  RU  Cablibration  step,  users  only  need  to  calibrate  the  band  one  time, 
because all the same band shares the same PA.  
 
Step 5: Click 
 to enter to RU Calibratiion page, refer to step 4 to finish RU calibration.  
 
NOTE1:  Make  sure  the  ANT  port  of  RU  is  connected  with  dummy  load  or  antennas  before  Calibration. 
Several RU can be calibrated simultaneously.