NOTE: There are three statuses for PA Service: NormalRecovery and Shutdown. If PA output power 
or reflected power exceeds the threshold, software will trigger Recovery:  
 
It will reset PA and then re-detect the PA output power and reflected power, if they are normal, the PA 
Service Status will turn to Normal, if PA output power or reflected power is still over the threshold, PA 
Service Status will turn to Recovery again. 
 
If PA output power or reflected power is still over the threshold after six times of PA Recovery, PA 
Service status will be Shutdown which will need to be reset manually. Reset at Management > PA 
Reset. 
 
 
Figure 32: RF Unit Detail Information 
 
5.2.2 
[COMMISSIONING] 
A work flow of the commissioning process is shown on [Commissioning] Screen. Click the [Start] button, 
the software will guide you through the commissioning step by step. For details, please refer to chapter 
5.3. 
 
Figure 33: [Commissioning] Screen