6.2  TROUBLESHOOTING 
 
Following installation and commissioning, occasional operation tasks to handle alarms may be required: 
 
Table 9: Monitor Unit Alarms Diagnosis 
Alarm condition 
Diagnosis 
RF Unit Alarm 
 
Check RF Unit alarm on WEB GUI. 
Ext Alarm  
 
Check to make sure if the external device connected is working normally. 
Fan Alarm 
 
Check to make sure the fan is working normally. 
Over- 
Temperature 
alarm 
 
Check temperature on WEB GUI 
 
If device temperature is over threshold, make sure environment temperature is within the 
envireonment temperature range that device supported (-20~40
℃). Apply climatic protection 
to the system under severe environment. 
 
Table 10: RF Unit Alarms Diagnosis 
Alarm condition 
Diagnosis 
Over DL P_in 
Alarm 
 
Test DL input power of the alarm RF Unit, if it is higher than threshold, changing the threshold 
value; when the DL input power is more than -40dBm, it is recommended to  add an external 
attenuator with proper attenuating value. 
PLL Alarm 
 
Check device on WEB GUI; 
 
Restart the device, if the PLL alarm is not fixed, replace the RF Unit. 
LNA Alarm 
 
Check device on WEB GUI; 
 
Restart the device, if the LNA alarm is not fixed, replace the RF Unit. 
DL PA alarms  
 
Check PA Service Status on WEB GUI RU page,  
 
If it is [Recovery], reset PA on WEB GUI Management page, then read RF Unit output power: 
If output power is exceed threshold, need to reduce gain or input power; if output power is 
normall, check whether antenna port VSWR is too high. 
 
If it is [Shutdown], Refer to Protection Shut Alram 
Protection Shut 
Alarm 
 
Make Sure the environment temperature is -20~40
℃ 
 
Reset PA, if PA service status turns to [Recovery], and then refer to DL PA Alarms. If PA still 
shutdown, the PA part maybe broken, please replace the RU. 
 
 
End of Section