USER MANUAL FOR COMFLEX 6100 
 
ENU STATUS : 1-0-0 
Copyright - refer to title page 
Page 56 
 
 
 
 
 
Figure 72: Dev Info & Date/Time 
 
Dev Info mainly used to record device location and Date/Time provid a time reference. Mouse click the 
Config Value of Date/Time to auto receive the computer time. 
 
NOTE:  Make  sure  all  the  ANT  ports  of  RUs  are  connected  with  dummy  load  or  antenna  system 
before proceeding to step 4. 
 
 
Step 4: Click 
 to enter to MU Calibratiion page after finishing Parems Setting.  
 
  Select a frequency band that need to calibrate from the table in the middle of the page. 
  Read Tip1 on the left side and click 
 of Tip 1 
  Input signal to a RF port of RFU which you want to calibrate. 
  Read Tip2 on the left side and enther the input power in the box (Suggested input power 10-
30dBm). Input power has to be >10dBm for successful calibration. 
  Click 
  Tip of MU calibration finish will show up on the left of the page, and calibration results will 
show in the table. 
  NOTE: Each RFU needs 
to be calibrated; click “More” at last step of process to calibrate next 
RFU.