ENU Status : 1-1-2
7.3 APPENDIX C: OVERDRIVE PROTECTION PROCEDURE
DL output power level >
shutdown protection power
threshold
Y
threshold persistent time > 5s
100% (time can set)
Y
Automatic shutdown
protection ON (RF switch
OFF)
Shutdown protection time >
15mins (time:10mins~24hrs)
Y
Y
Restart RF signal switch
Threshold overtime
Shutdown protection time
Clean shutdown protection
count
shutdown protection time
duration > 3 times (times: 1~255
available)
Y
Shutdown protection
alarm: permanent
shutdown
N
N
N
Shutdown protection count + 1
Set timer of shutdown protection time
End
Threshold overtime
Clean shutdown protection
counter
N
延延延延延延延延延延延
System initiation
RF signal “ON” manually
Reboot automatic
shutdown protection
procedure
N
Y
Threshold overtime
Shutdown protection
time
Clean shutdown
protection count
protection count
NOTE: 1. Independent control for each channel (850/1900/700)
2. Activate RF signal switch manually when the system is under permanent shutdown.
3. Overdrive protection procedures will be activated after manually turning on RF
2. Activate RF signal switch manually when the system is under permanent shutdown.
3. Overdrive protection procedures will be activated after manually turning on RF
Overdrive Protection
Procedures
DL output power level >
shutdown threshold
Over threshold duration reaches
5 secs(Duration configurable)
and all detections over threshold
No overdrive detected
when detection is over.
Shutdown counter clear to
null
Overdrive protection
activated, RF switch off.
Overdrive protection counter + 1
Start timer of overdrive protection
Overdrive protection counter > 3
(Range: 1~255)
Overdrive protection duration >
15mins ( Range:10mins~24hrs)
Irreversible RF swtich
turned off, overdrive
protection alarm is triggered
Turn on RF switch
Reset over threshold duration timer
Reset overdrive protection duration timer
Reset overdrive protection counter
Extra time until RF
stablized
Reset over threshold
duration timer
Reset overdrive
protection duration
timer
Reset overdrive
protection counter
Reactivate overdrive
Protection Procedures