INSTALLATION GUIDE FOR RD-2020 
 
 
 
RD-2020 CDMA QI 
Copyright - refer to title page 
Page 29
ENU Status : 1-0-0 
 
 
 
Commissioning Tasks 
Observation 
1.  On-line and Inquiry status 
z
 
Connect to repeater from PC via OMT. 
2.  Set Channel No. 
 
z
 
Keep RF switch ON and set the channel number of the repeater’s 
operating frequency. 
3.  Adjust Downlink Output 
Power and align donor 
antenna 
z
 
Observe DL input power from measured value. Align the direction of 
donor antenna until the DL input power reading is maximized. 
z
 
Note: To ensure that the measured DL input power is accurate, one 
should set the DL ATT to “0” before performing the check. 
4.  Configure [Equipment ID] 
z
 
Go to [Properties Info] and set [Equipment ID]. 
5. Comm. Config 
z
 
Enable the power supply by selecting “On” in [RF] -> [Switch]; go to 
[Properties Info.] -> [Comm. Config.] and set OMC Phones No. , the 
service No. of SMSC, Report Mode. 
6. Select Monitoring 
Parameters 
z
 
Select the equipment controlled and monitored parameters. 
z
 
If the external devices are connected to the equipment for 
management, please enable in the [External Alarm Info.] Interface. 
7.  Test coverage area field 
intensity and adjust 
service antenna. 
 
z
 
Use test-handset to verify field intensity within the coverage area. If 
needed, realign the service antenna to achieve the desired 
coverage. 
z
 
Note: If during operation, the equipment gain could not be set to 
maximum or the output power is not high enough due to insufficient 
donor and service antennas isolation, then the antennas’ position 
should be changed to increase isolation. If the output power is too 
high and ALC is activated, then adjust the DL ATT to achieve 
optimal DL Gain.  
8.  Verify UL gain and ensure 
test call produces good 
voice quality and there is 
no interfering BTS 
z
 
Adjust UL gain and perform test calls. Typically, the UL gain is set 
around 5dB less than DL gain. Perform test calls in the coverage 
area while adjusting UL gain if required.  
z
 
Note: If the repeater is near the BTS and the test call performance 
is poor, this may be due to UL noise interference to the BTS. Users 
can calculate and determine if the repeater UL noise will interfere 
with the BTS. 
z
 
Verify again that there is no unacceptable interference to BTS. 
Table 7: Commissioning 
 
 
 
 
 
 
 
End of section