Comba Telecom Ltd. RD-8132 Manual De Usuario

Descargar
Página de 27
USER MANUAL FOR RD-8132  
 
 
RD-8132 QI 
Copyright - refer to title page 
Page 21
ENU Status : 1-0-0 
 
 
[00~FF]. 
For the system located with single equipment, the Site Sub ID should be FF.  
For Master-Slave system, the Site Sub ID for Master Unit is 00, and the Site Sub 
ID for each Slave Unit is represented in the range of [01~FE] in ascending order. 
e.g. Master Site ID: 00, Slave Site ID: 01 
 
 
3.4.2 COMM. CONFIG 
If the equipment is to be monitored by OMC software over 
w
ireless GSM / CDMA network, users must 
finish the [Comm. Config.] in the next step. 
 
The Comm. Config information requires to be manually entered by users after successful connection to the 
equipment. 
 
 
Figure 22: Com. Config. 
See the table below for configuration details of each parameter. 
 
Item  
Description 
Checking Control 
Select “Enable” or “Disable” from the drop down menu as shown to enable or 
disable the Phone Number Authentication feature. Refer to [Phone No.] in 
details. 
OMC Server IP 
Based on the current network conditions, users can enter the IP address 
information of the equipment, which is connected to the OMT/OMC via 
Ethernet. This connection via Ethernet is not available at this stage.  
Phone No. 
This is designed for authentication purpose when remote connection via 
modem is required. It is the phone number to dial the equipment. Only the 
phone number pre-defined in this field, will it be allowed to dial the equipment. 
It is required to manually enter the phone number. Up to 5 phone numbers 
are allowed. The use of phone number authentication can avoid unauthorized 
use of the OMT. In addition, it can prevent the equipment receiving piles of 
spam short messages, thus help the operator greatly reduce the cost. 
Report Config 
The Report No. is the SIM card number of the modem built into the OMC 
Server computer.The equipment will send alarm SMS to this number.   
If remote communication is needed via modem, users have to enable SMS 
mode and set the report phone No. by entering the SIM card number of the 
equipment built-in modem. 
SMSC No. 
It specifies the SMS center. Users have to set the service No. of SMSC for 
the first installation, so that the alarms can be sent to OMC.