Comba Telecom Ltd. RS-5180 Manual De Usuario
R S - 5 1 8 0 C D M A 8 0 0 / 1 9 0 0 D u a l B a n d I n d o o r F i b e r O p t i c
R e p e a t e r
Comba Telecom
Edition
2.0
Date
2001-06
9 of 31
There are 4 downlink RF output ports and 4 uplink RF input ports on the front panel of the
Master Unit. Downlink and uplink are connected with 4 Interface Units through RF cable as
shown in figure 2.3-1.
Figure 2.3-1 Master Unit Panel Diagram
(1) Interface Unit (RS-5180-F)
Functions of Interface Unit include: uplink optical and electric conversion, showing the alarm
signal from Remote Unit and downlink optical dividing output.
1 Interface Unit has 4 couples of uplink optical input /downlink optical output ports to connect
with 4 Remote Units through optical fiber (figure 2.3-2).
Alarm function:
1. Each Interface Unit has a Optical Signal Transmitting Detection module. If no Optical
signals are sent, the red indicator on the panel will be on.
2. There is a Optical signal Receiving Detection module corresponding to each Remote Unit. If
no Optical signals are received, the correspondent will be off. When any Remote Unit or