3.  System Installation 
3.1.  Installation of Master Unit 
3.1.1 Dimensions 
Master unit rack is a standard  19 "  “portable frame ”. Its  external 
dimensions are as follows: 
564mm 
800mm 
380mm 
Distance between screw fixing holes on the base of the rack are:   
Left to right: 524 mm   Front to back: 322 mm 
 
3.1.2 Space Requirements 
Master unit should be located indoor so that the space for maintenance 
and ventilatio n is ensured. Hence, it is suggested that the back and side of 
rack should be at least 80~100cm away from wall or other System.   
The place should have good ventilation, with ambient temperature of  0
~40   a n d  relative humidity 
8 5 % .   Direct sunlight on the master unit should be 
avoided. 
 
3.1.3 Installation Method 
When shipped out of factory, the Master Unit is put into the cabinet 19 "  
6U  s t a n d a r d   r a c k
 while Interface Unit and power supply unit are put