Comba Telecom Ltd. RS-5180 Manual De Usuario
R S - 5 1 8 0 C D M A 8 0 0 / 1 9 0 0 D u a l B a n d I n d o o r F i b e r O p t i c
R e p e a t e r
Comba Telecom
Edition
2.0
Date
2001-06
13 of 31
3. System Installation
3.1. Installation of Master Unit
3.1.1 Dimensions
Master unit rack is a standard 19 " “portable frame ”. Its external
dimensions are as follows:
W
H
D
564mm
800mm
380mm
Distance between screw fixing holes on the base of the rack are:
Left to right: 524 mm Front to back: 322 mm
3.1.2 Space Requirements
Master unit should be located indoor so that the space for maintenance
and ventilatio n is ensured. Hence, it is suggested that the back and side of
rack should be at least 80~100cm away from wall or other System.
The place should have good ventilation, with ambient temperature of 0
~40 a n d relative humidity
≤
8 5 % . Direct sunlight on the master unit should be
avoided.
3.1.3 Installation Method
When shipped out of factory, the Master Unit is put into the cabinet 19 "
6U s t a n d a r d r a c k
while Interface Unit and power supply unit are put