Comba Telecom Ltd. RX-7W22-A Manual De Usuario

Descargar
Página de 55
INSTALLATION GUIDE FOR RX-7W22 
 
ENU STATUS : 1-0-0 
Copyright - refer to title page 
Page 51 
 
 
 
 
7.4 
APPENDIX D: TROUBLESHOOTING QUICK GUIDE 
 
Alarm list: 
 DL PA alarm
VSWR alarm
Over Temperature alarm
Low Input alarm
Antenna Malfunction
Dry contact alarm
Shutdown alarm
High input alarm
Signal Booster Failure
Dry contact alarm
LNA alarm
PLL alarm
 
Figure 46: Alarm list 
 
Troubleshooting: 
Alarms 
Causes and actions 
Low input 
(for DT port) 
DT composite input power lower than -80dBm will trigger the alarm 
1.  Donor antenna/passive system failure 
2.  Wrong channel frequency setting 
3.  Site is not commissioned yet 
VSWR 
Service antenna/passive system failure 
Over temperature 
Environment temperature shall be lower than 140degF (60degC) 
PLL 
(Phase lock loop) 
Hardware failure, RMA the equipment 
LNA 
(Low noise amp.) 
Hardware failure, RMA the equipment 
1.  Handling RF connectors when RF power is ON may damage LNA 
2.  High power injection to DT/MT port may damage LNA 
DL PA 
(Downlink amp.) 
Fix any other existing alarms first, then reset PA (see next page) 
If alarm still exists, RMA the equipment 
Shutdown 
Other critical alarm causes the equipment shutdown 
Follow instructions to fix other alarms first 
High input 
(for DT port) 
Check input power to DT port, the power shall be lower than -30dBm 
1.  Avoid other inference 
2.  Put attenuator between antenna and PS BDA, if donor signal is high