Opticon Sensors Europe BV H32 Manual De Usuario

Descargar
Página de 29
Opticon 
H - 32  
Specifications Manual 
 
 
 
 
 
18 
9.  Technical Specifications MDI3100 
 
Emit aiming light of the MDI-3100-SR to the center of a bar code for scanning. The conditions for technical 
specifications are as follows, unless otherwise specified in each section.  
 
<Conditions>  
Ambient Temperature and Humidity                  
 
: Room temperature and room humidity 
Ambient Light  
: 100 ~200 lux (on the surface of a bar code)  
Pitch Angle  
: α= 0°  
Skew Angle  
: β = 15°  
Tilt Angle  
: γ = 0°  
Curvature  
: R = ∞  
Power Supply Voltage  
: 3.3 and 5.0 V  
PCS (1D and 2D)  
: 0.9 or higher  
Scanning Test  
: Accept the performance with 90% or more 
success rate for 10 tries of scan. One 
scan should be tested within 2 seconds 
Bar Code Test Sample (1D and 2D)  
: Specified below  
 
< Test chart >  
For 1D codes, OPTOELECTRONICS test samples  
For GS1 Databar, stacked codes and 2D codes, printed by a dedicated printer for bar code 
 
9.1.  Print Contrast Signal (PCS) 
PSC 0.3 or higher  
 
<Conditions>  
MRD  
: 32% and higher  
(70% or higher reflectivity of space and 
quiet zone)  
Distance  
 130 mm from the front edge of the 
camera module  
Bar Code Sample  
: UPC specified in Chapter 8. 
(Resolution: 0.33 mm, PCS: 0.3)  
 
PCS = Reflectance of white bar-Reflectance of black bar  
                                Reflectance of white bar 
 
9.2.  Minimum Resolution 
1D Code    
: 0.127 mm (5 mil)  
Code 39 specified in Chapter 8  
GS1-Databar  
: 0.169 mm (6.7 mil)  
GS1 Databar-Limited specified in Chapter 8  
Stacked Code  
: 0.169 mm (6.7 mil)  
PDF417, GS1
 Databar-Limited Composite specified in Chapter 8  
2D Code    
: 0.212 mm (8.4 mil)  
OR Code and Data Matrix specified in Chapter 8