Opticon Sensors Europe BV H32 Manual De Usuario
Opticon
H - 32
Specifications Manual
6
4. Environmental Specifications
4.1. Operating Temperature and Humidity
Temperature: -10 to 50° C
Humidity: 20% to 80% RH
4.2. Charging Temperature
Temperature: 0 to 40° C
4.3. Storage Temperature and Humidity
Temperature: -20 to 60° C
Humidity: 20% to 90% RH
4.4. Ambient Light Immunity
Decoding performance is guaranteed when the range of illumination on a barcode surface is
between zero and the following values:
between zero and the following values:
Incandescent light
4,000 lx
Fluorescent light
4,000 lx
Sunlight
80,000 lx
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
PCS = 0.9, Resolution = 0.25 mm, Quiet Zone = 15 mm,
Symbology = 9-digit Code 39, N/W Ratio = 1:2.5
Distance
96 mm from the edge of the scanner
Angle
α = 0° β = 15° γ = 0°
Curvature
R = ∞
Direct light or specular reflection from a light source should be prevented from entering the
acceptance area.
acceptance area.
Note:
α, β and γ respectively represent pitch, skew and tilt. Please see section 8 for how
these values are defined.
4.5. Static Electricity
Air discharge:
± 8 kV MAX (No malfunction)
Contact discharge:
± 4 kV MAX (No malfunction)
The criteria minimum performance level (or the permissible performance loss) is specified by the
manufacturer, then either of these may be derived from the product description and documentation,
and by what the user may reasonably expect from the H-32 if used as intended.
manufacturer, then either of these may be derived from the product description and documentation,
and by what the user may reasonably expect from the H-32 if used as intended.
Performance criterion A
During and after the test the H-32 shall continue to operate as intended without operator
intervention. No degradation of performance or loss of function is allowed below a minimum
performance level specified by the manufacturer when the H-32 is used as intended. The
performance level may be replaced by a permissible loss of performance. If the minimum
performance level or the permissible performance loss is not specified by the manufacturer,
then either of these may be derived from the product description and documentation, and by
During and after the test the H-32 shall continue to operate as intended without operator
intervention. No degradation of performance or loss of function is allowed below a minimum
performance level specified by the manufacturer when the H-32 is used as intended. The
performance level may be replaced by a permissible loss of performance. If the minimum
performance level or the permissible performance loss is not specified by the manufacturer,
then either of these may be derived from the product description and documentation, and by