Opticon Sensors Europe BV OPL9813 Manual De Usuario

Descargar
Página de 24
Opticon
OPL 9813
Preliminary Specifications Manual
10
8.3. Scan Area and Resolution
8.3.1.
Depth of Field
The depth of field is measured from the edge of the data collector. The
scanning range is within the circular arc centered on the scan origin.
Figure 2: Depth of field
Symbology
Resolution (mm)
Decode Depth (mm)
PCS
Code 39
1.0
60–300
0.9
Code 39
0.5
35–210
0.9
Code 39
0.25
35–120
0.9
Code 39
0.15
35–70
0.9
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
N/W ratio:
1:2.5
Angle: 
α = 0°, β = 15°, γ = 0° 
Curvature: 
R = ∞