Connector Panel
The GW1200 Gateway has three connectors on the connector panel.
Note
When both PoE and external power supplies are used the external power source
is the primary power source.
is the primary power source.
(#1) Ethernet LAN Connection: RJ-45 connector. In a configuration with a physical
Ethernet cable connection to the LAN, the network cable is attached here.
Ethernet cable connection to the LAN, the network cable is attached here.
The GW1200 supports 100 Mb Full duplex communications. The Ethernet Network
Switch must be configured to Auto Negotiation mode for the Gateway to operate at 100
Mb.
Switch must be configured to Auto Negotiation mode for the Gateway to operate at 100
Mb.
(#2) Power Jack: Accepts an input voltage of 24-48V DC. This is a standard 5 mm (outer)
2.5 mm (internal) jack connector for direct power supply. A power adapter is not
supplied with the Controller and can be purchased separately. When PoE is used, this
connector becomes redundant.
2.5 mm (internal) jack connector for direct power supply. A power adapter is not
supplied with the Controller and can be purchased separately. When PoE is used, this
connector becomes redundant.
(#3) IN/RS-232 and OUT/RS-232 Connector: RJ-45 connector. RS-232 is used as a
console interface with the Exciter Manager Application (to change the IP address, for
example). For this option, a special 10-pin RJ45 to DB9 serial cable (AeroScout PN
40031500000) is required.
console interface with the Exciter Manager Application (to change the IP address, for
example). For this option, a special 10-pin RJ45 to DB9 serial cable (AeroScout PN
40031500000) is required.
(#4) IP Reset: Restores the Gateway's IP address to the factory default value.
Note
Inputs and Outputs are currently not in use.