Radwin Ltd. JETDB5X3X Manual De Usuario
RADWIN 5000 Installation Guide
Release 4.9.30
2‐7
SU PRO/AIR Units
Installation Steps
2.3.3 SU PRO/AIR Units
a. Click Configure
b. Click Network
c. Enter new IP Address, Subnet Mask, and Default Gateway.
d. Click Apply All and exit browser.
e. From a command line, ping radio unit using new IP address to verify change.
f.
Once you are finished with the steps above, disconnect the radio unit and prepare it
for deployment in the field.
for deployment in the field.
2.4 Check items to be installed
•
Radio unit + mounting kit
•
2 LPUs for each radio (recommended)
•
PoE (if outdoor, requires mounting kit)
•
CAT‐5e cables
•
Grounding cables (10 AWG) for radio unit, LPUs and outdoor PoE (if used)
•
External antenna + mounting kit (if using an external antenna for LFF or SFF units)
•
RF cables (if using an external antenna for LFF or SFF units)
•
Turbo Gain antenna (if using this antenna for the SU PRO/AIR unit)
2.5 Prepare Tools
•
Crimping tool
•
Spanner/wrench 13mm (1/2”)
•
Cable ties
•
Sealing material
•
Waterproofing tape (like Scotch 23)
Alternatively, you can use the WINTouch smartphone application to change the IP
address. Log on to WINTouch and follow the instructions.
address. Log on to WINTouch and follow the instructions.
FOR REGULATORY APPROVAL ONLY