Chapter 
 
5  Diagnostics and Troubleshooting 
WinLink 1000  Installation and Operation Manual 
5-4 Running 
Diagnostic 
Loopbacks
 
 
3.  Click OK to activate a loopback. 
WinLink 1000  activates selected loopback. A loopback status 
arrow in the Main menu turns green to indicate an active 
loopback.  
Î
 
To deactivate a loopback: 
• 
From the From the Local or Remote drop-down box of the 
Loopbacks dialog box, select None and click OK. 
A loopback is deactivated and the corresponding status arrow in 
the Main menu becomes dimmed. 
 
Figure 
 
5-2.  Loopbacks Dialog Box 
Local External Loopback 
Local WinLink 1000  can be set to an external loopback to test the local 
E1/T1 port and its connection to the local side user equipment. In this 
mode, data coming from the local user equipment is looped back to it 
(see 
Figure 
 
5-3
). This loopback is initiated from a management station 
connected to the local unit.