Chapter 5  Diagnostics and Troubleshooting 
WinLink 1000 Installation and Operation Manual 
3.  Click OK to activate a loopback. 
WinLink 1000 activates selected loopback. A loopback status 
arrow in the Main menu turns green to indicate an active 
loopback.  
Π
To deactivate a loopback: 
• 
From the From the Local or Remote drop-down box of the 
Loopbacks dialog box, select None and click OK. 
A loopback is deactivated and the corresponding status arrow in 
the Main menu becomes dimmed. 
 
Figure 5-2.  Loopbacks Dialog Box 
Local External Loopback 
Local WinLink 1000 can be set to an external loopback to test the local 
E1/T1 port and its connection to the local side user equipment. In this 
mode, data coming from the local user equipment is looped back to it 
(see 
). This loopback is initiated from a management station 
connected to the local unit. 
5-4 