CipherLab Co. Ltd. 1660 Manual De Usuario
114
End Programming Format
1600 Series Barcode Scanner
User Guide
DATA LENGTH
By default, barcodes of any length (character count) are eligible for data editing.
You may specify a value from 0 to 255.
When zero is given to both, the scanner will not perform the length qualification.
1) Read the labels for Max. /Min length separately.
2) Read the “
Decimal Value
” label on page 123 for the desired length.
3) Read the “Validate” label on the same page to complete this setting.
MATCHING STRING & LOCATION
By default, no matching string is specified, and therefore, it is disabled. You may enable
this feature by specifying a matching string; up to four characters are allowed.
this feature by specifying a matching string; up to four characters are allowed.
When the Matching String Location is zero, the scanner will only check for the existence of the
matching string in the barcode data.
matching string in the barcode data.
You may specify a value from 1 to 255 to indicate where the matching string starts in the
barcode data.
barcode data.
UPC-E Applicable
UPC-E Addon 2 Applicable
UPC-E Addon 5 Applicable
Max. Length
Min. Length