CipherLab Co. Ltd. 1660 Manual De Usuario

Descargar
Página de 150
114
 End Programming Format 
1600 Series Barcode Scanner 
User Guide
                                                                         
DATA LENGTH 
By default, barcodes of any length (character count) are eligible for data editing.   
You may specify a value from 0 to 255. 
When zero is given to both, the scanner will not perform the length qualification. 
1) Read the labels for Max. /Min length separately. 
2) Read the “
Decimal Value
” label on page 123 for the desired length.   
3) Read the “Validate” label on the same page to complete this setting. 
MATCHING STRING & LOCATION 
By default, no matching string is specified, and therefore, it is disabled. You may enable 
this feature by specifying a matching string; up to four characters are allowed. 
When the Matching String Location is zero, the scanner will only check for the existence of the 
matching string in the barcode data. 
You may specify a value from 1 to 255 to indicate where the matching string starts in the 
barcode data. 
UPC-E Applicable 
UPC-E Addon 2 Applicable
UPC-E Addon 5 Applicable 
Max. Length 
Min. Length