CipherLab Co. Ltd. 1862 Manual De Usuario

Descargar
Página de 175
 
 
51
 
 
 
Chapter 2
   Communication Interface 
 
2.4 BLUETOOTH
®
 SPP MASTER 
As a SPP master device, RFID Reader will be able to resume connection with the host 
computer upon powering on again, as long as the host application is running. If RFID 
Reader fails to resume connection, it will try every 5 seconds to re-connect to the host 
computer unless you issue the “#@bt_reset” or “#@sys_ldstbl=” command. 
For Bluetooth
®
 SPP Master Connection, refer to 
Note:  In SPP Master Mode, RFID Reader has to connect within the specified period of time 
(2 minutes by default). During the connection, the RFID Reader will enter Power 
Saving Mode. It will automatically power off when the Auto Shutdown time is 
reached. Refer to 
2.4.1 ACTIVATE BLUETOOTH
®
 SPP MASTER MODE 
How to connect with the target machine? 
Two parameters are necessary using “#@bt_target=” command for SPP Master connection. One is 
to configure connection type as SPP Master; the other is MAC ID of the target machine. 
 
Command: 
#@bt_target?\r  
Purpose Get 
Bluetooth
®
 Target Machine 
Response OK,[m],[n]\r 
[m]: Bluetooth
®
 Type, ‘0’ – SPP Master, ‘1’ – 3610 
[n]: MACID of target Machine or S/N of 3610 
ERR,[code]\r 
#@bt_target=[m],[n]\r  
Purpose Set 
Bluetooth
®
 Target Machine 
Response OK 
ERR,[code] 
 
Exit SPP Master Mode 
To stop such re-connection, you can issue the “#@bt_reset” command so that the current 
connection record (= MAC ID) will be cleared. Connection type will also be restored to default (SPP 
Slave). Go through the whole process in 
 to establish a new WPAN 
connection.