8
 TECHNICAL DATA 
48 
OPTIWAVE 1010
www.krohne.com
09/2014 - 4003537401 - MA OPTIWAVE 1010 R01 en
8.2  Technical data
INFORMATION!
The following data is provided for general applications. If you require data that is more 
relevant to your specific application, please contact us or your local sales office.
Additional information (certificates, special tools, software,...) and complete product 
documentation can be downloaded free of charge from the website (Download Center).
Measuring system
Measuring principle
2-wire loop-powered level transmitter; C-band (6 GHz) FMCW radar
Application range
Level measurement of clean liquids
Primary measured value
Distance and reflection
Secondary measured value
Level and volume
Design
Construction
The measurement system consists of a wave guide connection and a signal 
converter
Options
Weather protection
Measuring range
0...5.3 m / 0...17.4 ft (max. 8 m / 26.2 ft on request)
Top dead zone
Minimum value: 300 mm / 11.8¨ from the process connection
User interface
User interface
PACTware™
Measuring accuracy
Repeatability
±
1 mm / ±0.04¨
Accuracy
±
10 mm / ±0.4¨
Reference conditions acc. to EN 61298-1
Temperature
+15...+25°C / +59...+77°F
Pressure
1013 mbara ±50 mbar / 14.69 psia ±0.73 psi
Relative air humidity
60% ±15%
Target
Metal plate in an anechoic chamber