8
 TECHNICAL DATA 
54 
OPTIWAVE 1010
www.krohne.com
09/2014 - 4003537401 - MA OPTIWAVE 1010 R01 en
8.4  Pressure ratings
This data is only applicable to the flanged version of the device.
WARNING!
Make sure that the devices are used within their operating limits. This will depend on the device 
version, feedthrough material and process seal materal.
EN flanges
Figure 8-4: Pressure / temperature rating (EN 1092-1), flange connections, in °C and barg
Figure 8-5: Pressure / temperature rating (EN 1092-1), flange connections, in °F and psig
1  p [barg]
2  T [°C]
3  p [psig]
4  T [°F]
5  Flange connection, PN16
6  Flange connection, PN40