Norsat International Inc. 5200-KUAA-ID Manual De Usuario
158
Table 6
lists the type and meaning of each status indicator on the Status Screen.
Table 6
Status Screen Indicators
Status Indicator
Type of Status Indicator
Description
SSPA Detected Power
information only
the measured output power of the
amplifier
amplifier
Delta Power Output
variable range alarms
difference in the requested power
versus the measured output power
versus the measured output power
Rx Downconverter Level
information only
Rx signal strength indicator
SSPA Current
variable range alarms
DC current the SSPA consumes
LNB Current
variable range alarms
DC current the LNB consumes
Ku–L DNC Current
variable range alarms
DC current the Ku to L–band
downconverter consumes
downconverter consumes
SSPA Temperature
variable range alarms
internal temperature of the amplifier
SSPA Fan Operation
binary alarm
indicates whether the fans in the
amplifier are turning
amplifier are turning
Paradise DC current
variable range alarms
DC current the modem consumes
Rx Downconverter Lock
binary alarm
The Local Oscillator PLL lock
status for the downconverter in the
Rx path must be locked to use the
Rx spectrum analyzer.
status for the downconverter in the
Rx path must be locked to use the
Rx spectrum analyzer.
Tx Downconverter Lock
binary alarm
The Local Oscillator PLL lock
status for the downconverter in the
Tx path must be locked to use the
TX spectrum analyzer
status for the downconverter in the
Tx path must be locked to use the
TX spectrum analyzer