Item
Index
Frequency band
l
2300 MHz ~ 2400 MHz
l
2496 MHz ~ 2690 MHz
l
3400 MHz ~ 3600 MHz (S3500)
l
3650 MHz ~ 3700 MHz (S3600)
Channel raster
100 KHz
Channel bandwidth
20 MHz
Physical Interfaces
l
2 optical interfaces
l
4 antenna interfaces
l
1 power interface
l
1 LMT Ethernet interface
l
1 AISG /dry contact interface
Antenna type
4-antenna
Protection
IP 65
3.3 Power Supply
ZXSDR R8964 supports -48V DC (-57V DC~-37V DC) power input.
3.4 Grounding Index
The grounding requirements of ZXSDR R8964 should be less than or equal to 5 Ω. The
grounding resistance can be less than 10 Ω in the areas where the number of thunderstorm
days is less than 20 a year.
3.5 Power Consumption
ZXSDR R8964 S3500 Typical Power Consumption:
l
270 W : (4*10 W @DL:UL= 3:1) .
l
240 W : (4*15 W @DL:UL=2:2) .
ZXSDR R8964 S2300/S2600 Typical Power Consumption:
l
170 W : (DL: UL= 2:2) .
l
260 W : (DL: UL= 3:1) .
ZXSDR R8964 S3600 Typical Power Consumption:
l
260 W : (4*10 W @DL:UL= 3:1)
3.6 Reliability
lists the reliability index of ZXSDR R8964.
3-2