Mobilicom ltd. MCU-30 Manual De Usuario

Descargar
Página de 51
 
 
MCU-30 User Manual
 
 
 
 
 
 
Page : 16 / 51 
This page contains information which is protected by copyright and is proprietary to Mobilicom Ltd. 
No part of this document
 may be used, copied, disclosed or conveyed to another party without prior written consent of Mobilicom Ltd
 
4.2  Rear View Connectors 
Main: 
MCU-30: A HR22-12WTRA-20P connector is used.  
MCU-30 Embedded: A Molex P/N: 5015715007 connector is used. 
The  data  connectors  include  10/100Mbps  ETHERNET  port  and  can  in  additional 
support Serial RS-232 port. 
 
Power:  
MCU-30: A LF10WBRB-4P connector is used. 
MCU-30 Embedded: A Molex P/N: 5023520600 connector is used. 
The  power  connecters  utilizing  7-14.5VDC.  The  connector  includes  Dual  Inputs  for 
Hot Swap during operation. 
 
CAUTION  –  Connecting  two  batteries  in  parallel  for  a  long  period 
might  cause  common  discharge.  For  hot  swap  connect  the  second 
battery and disconnect the first one after. 
 
 
CAUTION  –  When  an  MCU-30  is  carried  by  a  personnel,  environment 
temperature should not exceed 45°C (113°F) 
 
 
NOTE –Information about  the connectors pin assignment is available in 
Appendix C – Connectors Pinout  
 
LED: The MCU-30 LED indicates power up and link status