G-Way Microwave / G-Wave PS7W3790R Instrucciones de operación

Descargar
Página de 18
 
 
13 | 
P a g e
 
 
 
INSTALLATION 
 
 
DO NOT APPLY A.C. POWER TO THE UNIT  UNTIL CABLES ARE 
CONNECTED TO BOTH PORTS OF THE BDA AND THE ANTENNAS.  
 
 
1. 
Place the BDA in the cabinet. Using appropriate screws and anchors or attach the BDA to 
the wall at the four mounting holes on the side flanges  (special version not shown in this 
manual). 
 
2. Ensure that the isolation between the base station antenna and the mobile antenna 
should be at least 12 dB higher than the BDA gain  (Use the higher of the Uplink and 
Downlink gains reported on the BDA test data sheet).
 
 Isolation less than this value can cause gain ripple across the band. Isolation equal to 
or less than the BDA gain will give rise to oscillations which will saturate the amplifiers 
and possibly cause damage to the BDA.  
 
3. Connect the cable from the donor antenna to the BDA connector labeled “BASE” and the 
cable from the service antennas to the BDA connector labeled “MOBILE”. 
 
4. See main Panel of the BDA and verify that both of the Uplink and Downlink attenuation is 
set to 30 dB via dial Attenuator.   
 
5.  Connect the AC power cord to the BDA and then to the power source. Verify that the 
“Power ON” lamp is illuminated.  
 
Installation of the BDA is now complete. To adjust the gain controls to suit the specific signal 
environment, refer to the next section of the manual. 
 
Note:
 
For repeat installations of existing equipment, make sure the attenuation is 
positioned to its maximum setting (30 dB). After verification attenuation, follow the 
above steps starting with step 1.