OPERATION
 
 
Refer to Figure 4 & 5 for adjustment access location, connectors and labels
 
Variable Step Attenuator 
BDA gain that indicated in the spec can be reduced by up to 30 dB in 2 dB steps using the 
variable step attenuator. Gain adjustment is made with rotary switches located on the front 
panel  of the BDA enclosure. Arrows on the shafts of these switches point to the value of 
attenuation selected. BDA gain can be determined by subtracting the attenuation value from 
the gain reported on the BDA Test Data Sheet for that side of the unit.  The attenuators are 
labeled for Uplink and Downlink
 
ALC (Automatic Level Control)  
 
To minimize intermodulation products, each amplifier in the BDA contains an ALC feedback 
loop. The ALC circuit senses the output power and limits it to the factory preset level, as 
indicated in the specification.   
 
ALC function is located in each power amplifier. A red LED indicator located on the Front main 
panel (see figure 5) illuminates when output power meets or exceeds the ALC preset point.  
 
To establish proper operating gain on the Uplink and Downlink sides, start with the Downlink. 
Observe the red LED  indicator  on the Downlink amplifier. Units are shipping with maximum 
attenuation. Decrease attenuation one step at a time until the red LED is lit. Then, using the 
Downlink step attenuator, increase the attenuation until the red  LED  goes off. Repeat the 
process for the Uplink, and then repeat the process for the second band. This setup should be 
done under RF signal transmit for either path the level indicator is accurate to +/- 0.4 dB of the 
ALC set point.  
 
Verify the downlink in-building signal strength and the uplink signal strength at donor antenna 
meets requirements. Reduce the gain if needed.  
 
 
 
 
Note: Operation of BDA
 
at maximum gain with greater than -30 dBm 
average power incidents on the MOBILE or BASE ports could cause damage.