Aruba 370 Series Outdoor Access Points
| Installation Guide
13
Figure 14  
Completed Installation 
Disconnecting the Fiber-optic Cable
To disconnect the fiber-optic cable from the access point, perform the following steps.
1. Turn counterclockwise to loosen the sealing nut.
2. Pull the clip and seal out simultaneously.
3. Unscrew the gland body from the SFP port
4. Depress to release the latch on the cable and simultaneously pull the cable out of the port.
Verifying Post-Installation Connectivity
The integrated LEDs on the access point can be used to verify that the access point is receiving power and 
initializing successfully (see 
 and 
). For instructions on initial setup and software configuration, 
refer to the AP Software Quick Start Guide.
Electrical and Environmental Specifications
Electrical
Ethernet
One 10/100/1000Base-T auto-sensing Ethernet RJ-45 Interfaces
Power over Ethernet (IEEE 802.3at compliant)
Power
AC input voltage and current: 100VAC to 240VAC, 0.5A
Connect only to IEC 60950-1 or IEC60601-1 3rd edition products and power sources
Environmental
Operating
Temperature: -40ºC to 65ºC (-40ºF to 149ºF)
Storage
Temperature: -40ºC to 70ºC (-40ºF to 158ºF)
Humidity: 5% to 93% non-condensing
For additional specifications on this product, please refer to the data sheet at 
www.arubanetworks.com
.
Regulatory Model Name
The following regulatory model names apply to the 370 Series:
AP-374: APEX0374
AP-375: APEX0375