Hewlett Packard Enterprise Company ARUBA52 Manual De Usuario
Setup & Installation
15
Chapter 2
7/29/03 FINAL DRAFT—CONFIDENTIAL
Configure the Aruba 52
From the boot prompt, set the intended location for the Aruba 52:
If you performed the recommended site survey using the Aruba WLAN Switch’s built-in
planning tools, the location data for all access points and air monitors can be found on the
tool’s deployment screen (see the Aruba AirOS Software Guide).
planning tools, the location data for all access points and air monitors can be found on the
tool’s deployment screen (see the Aruba AirOS Software Guide).
If you plan to manually generate the location data, record the following information for each
access point and air monitor. It will be required when configuring the Aruba WLAN Switch.
access point and air monitor. It will be required when configuring the Aruba WLAN Switch.
apboot> setenv location
<building number>.<floor number>.<device number>
Building Number
A unique number (1-255) is required for each building in your campus.
Floor Number
Within any building, a unique number (1-255) is required for each floor.
Device Number
Within any floor, a unique number (1-65536) is required for each access
point or air monitor.
point or air monitor.
Device Description Note the intended function of the device (access point or dedicated air
monitor) and a brief description of its service location.
X, Y Coordinates
For each access point and air monitor, measure its X and Y position (in
feet) relative to the bottom-left corner of the building plan as seen from
overhead. For example:
feet) relative to the bottom-left corner of the building plan as seen from
overhead. For example:
Use the same fixed point and orientation for all floors in a building.
1
0,0
126
98
X
418 ft.
Y
262 ft.