Configuring EtherProx Entry 
EtherProx Entry 
Power Connections  
The EtherProx Entry reader contains an internal voltage regulator that requires an 
external power supply with nominal 12-volt output. The internal voltage regulator is 
capable of supplying at least 250 mA of current. The Power input is filtered, as well 
as Transzorb and reverse-voltage protected. Power is supplied to the reader by 
means of a J3 connector, as shown in Figure 1. 
 
Figure 1: Terminal and Power Connections 
 
Note 
The Phoenix Contact terminals for the power and data connections can 
accommodate two leads fitted into one terminal. 
The total cable length between the power supply and the reader depends on the 
type of cable you use and whether you connect an exit reader. Here are guidelines 
for determining the voltage: 
1. 
For long cable runs, use Table 1 to calculate the voltage drop of the cable 
between the power supply and the reader. 
EXIT 
READER
 
WIRE SIZE
 
VOLTAGE 
DROP
/100 
FT
 
VOLTAGE 
DROP
/100 
M
 
Y 18 
AWG 0.64V  1.95V 
Y 22 
AWG 1.6V  4.9V 
N 18 
AWG .38V 
1.17V 
N 22 
AWG 0.96V  2.9V 
Table 1: Voltage Table 
2. 
Subtract the result from the power supply’s output voltage. 