a) No.1  load cell is connected to V.R.I of box
b) the weight  deviation  among four points should be
within +/-1 digit      by a quarter of full capacity weight
c) When the deviation among four points on the body is over
+/-1 digit,     adjust variable resister of junction box
pertinently
  (example : If 100kg load is put on the platform, L/C
outputs
  are as follow)
  L/C : 100.1/ No.2 : 100.2/ No.3 : 99.7 /No.4 : 100.0
  Increase No.3 V.R of junction box and decrease No.2 V.R
and adjust      by repeating