Maintenance 
Preventive maintenance is the best method of ensuring long and trouble free operation. A 
general inspection should be conducted at regular intervals. 
Periodic cleaning 
Periodically wash all skin parts that are not regularly sanitized during and after each class, 
using warm soapy water or Virkon. 
Outer skin and moulded hair 
Most stains can be removed using warm soapy water, Virkon or Manikin Wipes (ethanol).  
However, the older the stains are, the more difficult they are to remove. Nonabrasive 
household cleaners that are safe for plastics may produce desirable results. It is wise to 
test other cleaning agents on a non-critical area, e.g., under the chest cover, before 
general use. Note that pigments from lipstick and ballpoint pens quickly travel into the 
plastic skin. Such stains may be impossible to remove. 
Clothes 
Hand or machine wash with soap or laundry detergent in warm water, max. 40°C (100°F). 
Iron with warm iron. May be dry cleaned. Please note that hot air dryer may cause 
garment shrinkage. 
Changing the pupils  
The simulator is delivered with a set of eyes containing normal pupils mounted in the 
head. A separate case contains 3 sets of plastic eye inserts (normal, constricted and 
dilated pupils) for use in simulating other conditions. To change the pupils in the airway 
head:  
1.  Remove the hair from the airway head by pulling back on the hair piece.   
2.  Detach the top of the face skin and fold back until the eyes are exposed.  
3.  With a thin blunt object, for example a screw driver, place the tip into the groove 
under the eye insert, and pull up to detach the eye from the skull 
 
 
 
4.  To insert the new eye position it in eye hole of the scull and press in until it snaps into 
place. 
5.  Reattach face and hair by reversing points 1 & 2 above 
Attaching the Airway Head  
In the event that the airway head needs to be removed or re-attached to the simulator’s 
torso perform the following: 
1.  Detach the simulator’s chest skin by pulling the skin away from the tabs 
2.  Carefully lay the skin to the side being careful not to apply excessive force to the cable 
attachments