CommScope Technologies LLC RP-A2014 Manual De Usuario
Chapter 4 Radio Point Installation
4-16
913020 10.05 April 2015
D
R
A
F
T
•
Rod, 3/8-inch threaded
•
Nut
•
Lock nut, nylon
Flown mount installation
1
Attach the threaded, 3/8-inch rod, cut to the required length, to the ceiling.
2
Install the nut on the rod.
3
Slide the bracket on the rod and install the nylon lock nut.
NOTE:
Be sure the bracket is tight between the nuts and there is enough clearance
at the end of the rod to attach the bracket to the Radio Point.
4
Attach the Airvana-supplied mounting bracket to the Radio Point.
5
Connect the Ethernet cable to the Radio Point.
Pole mount
The Radio Point can be pole mounted. This configuration is used for building where
there are no drop ceilings.
there are no drop ceilings.
3/8-inch rod
Nut
Nylon lock nut