4.9 Spillage Test
Test Item
Specification
Test Equipment
Spillage test
Unit shall be ON.
The keyboard shall be functional after
performing the liquid spill tests:
performing the liquid spill tests:
Pour the liquid from a funneled system from a
height of 3.0" above the keyboard over
between the G, B, and H keys. The funnel
should accurately dispense all the liquid at a
rate of approximately 4 Oz (116 cc) per minute
of elapsed time. The
height of 3.0" above the keyboard over
between the G, B, and H keys. The funnel
should accurately dispense all the liquid at a
rate of approximately 4 Oz (116 cc) per minute
of elapsed time. The
Keyboard shall remain idle for 60 seconds and
then the keyboard shall be tilted to drain the
liquid. Liquid for test:
then the keyboard shall be tilted to drain the
liquid. Liquid for test:
(1) 8.0 fluid oz. of hot coffee mixture (65C±5C)
(Coffee mixture shall be prepared by adding 4.0
gm. of sugar and 2.0 gm. of non-dairy creamer
to an 8.0 oz. cup of hot coffee.).
(Coffee mixture shall be prepared by adding 4.0
gm. of sugar and 2.0 gm. of non-dairy creamer
to an 8.0 oz. cup of hot coffee.).
(2) 1.0 fluid oz. of cold sugared Cola (15C ±5C)
(3) 350cc of water (24±2°C):Don’t shake
keyboard after complete spilling water, Pour out
water.
keyboard after complete spilling water, Pour out
water.
Pass Criteria
All keys on the keyboard are functional
Liquid effectively drains from the specific
keyboard liquid drain hole(s) Fail Criteria
Liquid does not pass through keyboard and
into the drain hole(s) and out the bottom of the
keyboard
keyboard
Spontaneous characters appearing on the
screen.
Repeating keys (a repeating key is a key cap
that is depressed and release once but
continues to scroll the character more than
once)
continues to scroll the character more than
once)
Non-Functioning keys
Drop machine