Zagg ZKLI Manual De Usuario

Descargar
Página de 34
3855 South 500 West Ste Q  |  Salt Lake City, Ut  | 84115 | 801.506.7081 
26
 
 
 
4.9 Spillage Test
 
Test  Item
 
Specification
 
Test  Equipment
 
Spillage test
 
Unit shall be ON. 
 
The keyboard shall be functional after 
performing the liquid spill tests: 
 
Pour the liquid from a funneled system from a 
height of 3.0" above the keyboard over 
between the G, B, and H keys. The funnel 
should accurately dispense all the liquid at a 
rate of approximately 4 Oz (116 cc) per minute 
of elapsed time. The 
 
Keyboard shall remain idle for 60 seconds and 
then the keyboard shall be tilted to drain the 
liquid. Liquid for test: 
 
(1) 8.0 fluid oz. of hot coffee mixture (65C±5C) 
(Coffee mixture shall be prepared by adding 4.0 
gm. of sugar and 2.0 gm. of non-dairy creamer 
to an 8.0 oz. cup of hot coffee.). 
(2) 1.0 fluid oz. of cold sugared Cola (15C ±5C) 
(3) 350cc of water (24±2°C):Don’t shake 
keyboard after complete spilling water, Pour out 
water. 
 
Pass Criteria 
 
  All keys on the keyboard are functional 
 
  Liquid effectively drains from the specific 
keyboard liquid drain hole(s) Fail Criteria 
 
  Liquid does not pass through keyboard and 
into the drain hole(s) and out the bottom of the 
keyboard 
 
  Spontaneous characters appearing on the 
screen. 
 
  Repeating keys (a repeating key is a key cap 
that is depressed and release once but 
continues to scroll the character more than 
once) 
 
Non-Functioning keys
 
Drop machine