…I/O Ports
Floppy disk attached to the parallel port does not work after
suspend/resume
Not all external floppy disk drives will work with the mobile
computer. Make sure all add-on device drivers are Advanced Power
Management (APM) aware.
PC SRAM cards are not readable on the mobile computer
If the SRAM card is reformatted on the mobile computer, read/write
operations will be successful.
• Verify the following lines are in your CONFIG.SYS:
“DEVICE=C:\WINDOWS\SYSTEM\CSMAPPER.SYS”
“DEVICE=C:\WINDOWS\SYSTEM\CARDDRV.EXE\SLOT=2”
Serial ports do not work consistently with Procomm Plus Version
2.00 or earlier
Procomm Plus Versions 2.01 and later do support 16550 buffered
UART operation. Upgrade software.
The system does not automatically detect COM3
This error can occur if COM3 is removed using Device Manager in
System Properties and then “Add New Hardware” is run. To prevent
this problem, open a DOS box and enter MODEM ON before running