Self-test  
International regulations require that Self-testing of the PLB should only be carried out 
in the first five minutes of any hour.  
 
Self-test  verifies  operation  of  the  PLB  by  checking  key  features  including  battery 
voltage and 406 MHz and 121.5 MHz alert transmitters. 
 
Important  
Each  self-test  draws  small  amounts  of  energy  from  the  battery  pack.  Unnecessary 
testing of the PLB may subsequently reduce the run time of the PLB in an emergency. 
On  average,  the  PLB  should  only  be  self  tested  12  times  per  year,  or  a  total  of  60 
times across the 5 year battery lifetime.  
 
To operate self-test, use the Test/OFF button, located under the flexible handle of the 
red anti-tamper cover.  
  
• 
Open the flip-top lid. Do NOT pull off the red anti-tamper cover. 
 
• 
Slide a finger under the flexible handle of the anti-tamper cover to locate the 
Test/OFF button.  
 
• 
Hold down the Test/OFF button for 10 seconds. 
• 
(red ON indicator light will illuminate) 
 
 
• 
Self-test pass is indicated by 3 flashes of the green indicator light and 
the alarm buzzer will sound.  
 
• 
A failed self-test is indicated by 3 flashes of the red ON indicator light  
 
• 
The PLB will switch off  once the self-test has finished 
 
 
 
 
 
 
 
Self-test 
 
 
 
 
 
 
 
 
 
   
                               
• 
Release the button and close the flip-top lid.