FreeWave Technologies Inc. 715712152112 Manual De Usuario

Descargar
Página de 54
 Global Transceiver Module (GXM) Wireless Data Transceiver User Manual 
LUM0031AA Version 
1.0 
23 
TurnOn/OffDelay 
(E)  
These settings are not utilized in the GXM. 
FlowControl (F) 
This menu specifies the hardware flow control for the Data port. The options for 0-3 
are described below. 
Menu Port Additional 
Information 
   0                        None               Default – No flow control 
   1 
RTS 
Uses Standard RTS/CTS control lines 
   2 
 DTR 
 
   3 
                DOT   
 
 
M
ODBUS 
RTU
 
T
IMING
 
The Modbus RTU setting causes the radio to wait for an amount of time, “gathering” data before sending 
that data out the radio link. 
With a Modbus RTU setting of 0 (Disabled), the radio will send data out its radio link as soon as the data 
is received into the serial port. 
With a Modbus RTU setting of 1, the radio will wait for a number of slots equal to 2 times the Master 
Packet Repeat
 setting before sending the received data out the radio link. For example, if Master Packet 
Repeat = 3
, the radio will wait for 6 slots, gathering data up the whole time. At the end of the 6 slots, the 
radio will send all received data in one “burst”. This is the appropriate setting for most Modbus RTU 
devices. 
With a setting of 2 and higher, the radio will wait for a number of slots calculated by the following formula: 
(Modbus RTU Setting + Master Packet Repeat Setting + 1) x 2 
For example, in a radio where the Modbus RTU setting = 2 and the Master Packet Repeat setting = 3
the radio will wait for “(2+3+1) x 2” slots, or 12 slots.
 
FreeWave Technologies, Inc. 
1180 S Flatiron Ct Ste F 
Boulder, CO 80501 
(303) 381-9200