Global Microwave Systems Inc. M2T-D3 Manual De Usuario

Descargar
Página de 41
 
100-M0113X1 Rev. 04-17-09                                                                                                   PAGE 11 OF 41 
 
 
1.  Install omni-directional antennas onto the M2T transmitter RF output port and 
at the receiver end Down-Converter(s) RF input port.  Note:  Transmitters 
should not be powered on
 without a load attached to the RF output 
connector. The internal PA could be damaged.
 
2.  Attach an SDI video source to the M2T SDI BNC video input. A composite 
signal can also be applied to the M2T I/O DB-44 connector using GMS break 
out cable, however keep in mind that the video source must match the group 
setting of the transmitter.  Refer to the software section 6.0 on the selection of 
the transmitter (M2T) video groups.  
3.  The MSR should be pre-configured from the factory (refer to the GMS web 
site for the online manual).  In short ensure the MSR is powered, has a cable 
from the ASI out to the decoder ASI input, that each tuner has a RF cable 
which runs to each block down converter (each tuner is provided power either 
through the MSR or locally) and is set to the same RF frequency as the 
transmitter.  
4.  Attach a video cable from the video out of the decoder to a video monitor. 
Refer to the decoder’s operational manual for proper setup. 
 
NOTE:  Before providing power to the M2T in the following step ensure 
to use a proper heat sink with adequate air flow or equivalent heat 
sinking method

 
5.  Provide power to the M2T (+12 Volts) using GMS break out cable (780-
C0291) which connects to the I/O DB-44 pin connector.  Power supply should 
be able to source approximately 2 amps.   
6.  Turn on the video source and video monitor equipment.  
7.  After approximately 30 seconds the link should be established and video 
provided by the source should be displayed on the monitor. An optional 
computer with the MSR control software installed can be used to monitor the 
receive parameters such as BER, MER and Signal to Noise. This connection 
can be through the USB or RS232 port.  
 
The initial checkout described above is simply to check the basic video operation 
of the M2T unit.  For further details on monitoring and controlling the M2T using 
GMS’ optional MS Windows-based M2T Configurator software program, see 
Section 6.0.