Global Microwave Systems Inc. VMT-F2 Manual De Usuario

Descargar
Página de 23
 
 
100-M0169X1 
11-15-11       
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 16 of 24 
 
www.cobham.com/gms 
 
 
 
PIN 
SIGNAL 
NOTES 
AUDIO GND 
AUDIO GND 
COMP INPUT 1 
Composite  Video  Input.    Must  be 
selected  with  GMS  Control  Software. 
Also used for S-VIDEO Input.   
COMP INPUT 2 
N/C.    Only  used  for  S-VIDEO  Input.  
Must  be  selected  with  GMS  Control 
Software. 
GND 
GND 
AUDIO LEFT 
Audio Left, W/ 2V Phantom Bias. 
10 
AUDIO RIGHT 
Audio Right, W/ 2V Phantom Bias. 
11 
GND 
GND 
12 
CHAIN CLK OUT* 
N/C. 
 
Chaining 
used 
in 
Repeater/Multiplexing    applications, 
contact GMS for details 
13 
CHAIN DATA 
OUT* 
N/C. 
 
Chaining 
used 
in 
Repeater/Multiplexing    applications, 
contact GMS for details 
14 
GND 
GND 
15 
RS232_DATA_Rx 
N/C.  RS232 for User Data, Rx 
16 
RS232_DATA_Tx 
N/C.  RS232 for User Data, Tx 
17 
RS232_CNTRL_Rx  RS232 for PC CONTROL Software 
18 
RS232_CNTRL_Tx  RS232 for PC CONTROL Software 
19 
2.8V uC 
N/C.  2.8V Output from Unit 
20 
GND 
GND 
21 
VBATT_IN 
Input Power to Unit: 5.9-18VDC 
Table 2 JST Connector (21 Pins) 
 
  Note:   
Table  2  references  Cable  780-C0449.    GMS  can  build  customized  cables  to 
customer  specifications  to  access  functionality  not  included  in  our  standard  cable.  
Customers can also choose to build their own cables. Contact GMS with any questions.
 
 
 
6.1.2.1  Phantom Bias for TIBBETTS Microphones 
 
The VMT does not provide a traditional separate bias voltage for surveillance microphones.  
Instead, we provide a 2V Microphone BIAS directly on the signal lines.  This is called phantom 
biasing  of  microphones  and  has  been  proven  to  work  with  TIBBETTS  151/251/351  series 
microphones  by  GMS.    See  TIBBETTS technical  application  notes  for  Phantom  powered  2-
wire connection for specific details, GMS standard breakout cable employs 2-Wire Option C.  
This wiring is in accordance with section 4.9.2 of RFP: E007216R and Attachment A of RFP: 
E007216R. 
 
In addition, to note, single ended line level audio can also be used instead of microphones.  
The user will want to lower the Audio Gain to “0dB” through the GMS control software when 
Line level audio is input.