6.6.5.
 
Power Ramp Tool
Power Ramp Tool
Power Ramp Tool
Power Ramp Tool    
The Power Ramp Tool determines the minimum power to activate a tag and 
can help determine tag quality. This activation power level can help 
determine the read range at various attenuation levels and, for AVI 
applications, can help determine the "read-zone" or an antenna pattern. 
The tool starts by configuring the reader to start transmitting at a high 
attenuation level (usually maximum allowed for reader) and decrements the 
level until it observes a response from the tag.  The transmitter is turned off 
and the minimum value to activate the tag for a given antenna and distance 
is reported. 
 
The Power Ramp controls include: 
 
Increment Rate (ms) 
– Time tool stays at a particular power level 
before incrementing to the next power level. 
 
Initial Attenuation Level (dBm) 
– Starting attenuation level. 
 
Attenuation Decrement (dBm) 
– Step-size for attenuation 
decrement. 
 
Antennas
 section allows you to select which antenna(s) to test with. 
 
Filter
 section allows you to apply a filter to only look for a particular tag.