DataSend Installation Instructions 
 
Model: DataSend900 GPRS 
 
BluTower Inc 
www.blutower.com 
US Offices –  
201 Shannon Oaks Circle, Suite 200, Cary, NC 27511 Tel 919-654-7352 
2855 South Pine Avenue, Ocala, FL 34471 Tel 352-624-8695 
© 2010 BluTower Inc. The information contained herein is the property of Blue Tower Communications Inc and is supplied without liability for errors or omissions. No part may be 
reproduced or used except as authorized by contract or other written permission. All other company names, brand names, and product names are the property of their respective holder(s). 
P/N DataSend900 PSTN Rev1 
Page 1 of 2 
 
Description 
 
The DataSend900 GPRS Unit is the central system control/data collection 
unit for a DataStream Radio network. The Network is designed to 
automatically and remotely gather readings from a number of Water 
Meters located within a defined area. 
 
Note Please refer to the Technical Manual for further information. 
 
Specification 
 
Power Supply:  
5Vdc 800mA 
Operating Frequency:  
902MHz to 928MHz (Frequency Hopping) 
GPRS Modem 
Quad Band PTRCB, FCC approved 
 
Required Equipment 
 
The following items are required for DataSend installation: 
• 
DataSend900 GPRS Unit. 
• 
5Vdc 800mA Power supply. 
• 
Antennas (part no  
• 
USB-A to USB-A Cable. 
• 
Simcard 
• 
Computer running Windows XP
®
.
 
• 
‘DataSend USB Configurator’ software.
 
 
Installation Instructions 
 
Note: DataStream Systems are intended to be professionally 
installed. Only a half-wave dipole antenna with a maximum gain of 
2.15dBi should be fitted to the product to meet the FCC regulations. 
The unit is designed to be wall-mounted and unattended in normal 
operation. 
 
To mount the unit: 
1. 
Remove the box lid; use a screwdriver to release each of the lid 
screws from the box. 
2. 
Insert the simcard into the simcard holder. The configuration process 
for the GPRS network settings are detailed within the Configuration 
Software Manual
 
3. 
Before fixing, ensure the Box is positioned so that the RF antennas 
may be orientated vertically (upwards). 
4. 
Fit antenna as shown and antenna as shown 
 
 
 
5. 
Using suitable wall mountings screw the box to the wall through the 
holes in the four corners of the box. 
6. 
Once the box is securely fixed to the wall and before refitting the Lid, 
connect a suitable 5Vdc Power Supply to the 2.1mm Power Jack. 
7. 
Using a suitable Type-A to Type-A USB Lead, connect the DataSend 
to a PC that has previously had the ‘DataSend USB Configurator’ 
installed. Ensure the PC is powered-on before connecting to the 
DataSend. 
Note There is a USB socket mounted inside the DataSend Box. 
8. 
Configure the System as shown in the  Configuration Procedure 
below. 
9. 
Once the System has been configured, disconnect the USB Lead. 
10.  Refit the Lid and fit the supplied blanking caps to cover the lid screws. 
11.  Finally connect the DataSend Box to a telephone line via the RJ11 
socket. 
 
 
Configuration Procedure 
 
The DataSend is visible to Windows as a ‘virtual Comport’. The ‘DataSend 
USB Configurator’
 program will attempt to automatically locate the correct 
Comport and connect to the DataSend unit. If it fails, an error message will 
be displayed and manual selection of the Comport may be required. 
Note connection failure will normally be caused by starting the program 
before the USB driver has fully initialized. If this is the case, simply 
restarting the program will fix the problem. 
Once a connection has been established, the program will read the 
existing configuration from the DataSend. A message will be displayed 
indicating if the configuration data has been successfully received. 
The DataSend may now be configured, as follows: 
1. 
Choose a unique ‘Network ID’. i.e. an ID that is not already used by 
an adjacent DataStream Network. This value must be different from 
the Default of 105,129,126,150. If you do not have any preference on 
the ID, press the ‘Generate ID’ button to obtain a random Network ID
2. 
Carefully edit the ‘DataRelay IDs’ list to match the DataRelay IDs that 
were recorded during installation. If there are any duplicate IDs in the 
list, an error message will be displayed. 
3. 
If required, enable the ‘Utility Mask’ option – see the ‘Configuration 
Software Manual’ 
for details of this option. 
Note if the ‘Utility Mask’ option is enabled, all the EndPoints need to 
be configured to transmit the correct Utility Code for the Nearest 
DataRelay. 
4. 
Set the required ‘Reading Interval’ – the frequency that the latest 
Endpoint data is retrieved from each DataRelay module. The 
minimum allowed interval is a function of the number of DataRelays 
in the Network. 
Note the configuration program will automatically calculate the 
minimum time required to get data from all the listed DataRelays and 
will not allow an interval setting below this value. It will also display 
the maximum length of history available with the selected interval (for 
most settings this will be 90 days). 
5. 
Ensure the PC’s clock is set to the correct time – this will be used to 
set the real-time clock (RTC) in the DataSend. 
6. 
Write the new configuration data to the DataSend by pressing the 
‘Write Configuration’ button. Once the DataSend has been 
successfully updated, a ‘Configuration Updated’ message will be 
displayed. 
Note it is recommended that all the DataRelays should be installed 
and powered-on before writing the new Configuration to the 
DataSend unit – the DataSend unit will transmit the required Network 
ID to each DataRelay as it is registered with the DataSend unit. 
7. 
Optionally import a previously generated route file by pressing the 
‘Import Route…’ button. This will automatically store a copy of the 
route file in a reserved area in the DataSend’s non-volatile memory.  
A large route file could take several minutes to copy, so a progress 
bar will be displayed during the transfer. 
Note the reserved area can store a maximum of 5119488 bytes, so 
the route file must be no larger than 5119488 bytes. The program will 
display a warning message if this size limit is exceeded. 
8. 
Finally, start the Network running by pressing the ‘Start Network’ 
button. 
 
See the ‘Configuration Software Manual’ for more details on the available 
settings.