C h a p t e r   7
O p e r a t i o n
7.4.8 Message details
Equipment status
S1F0: ABORT TRANSACTION (reader <-> host)
Used instead of an expected reply to abort a transaction. Function 0 is defined in 
every stream and has the same meaning in every stream.
S1F0 W . * Header only
S1F1: ARE YOU THERE REQUEST (reader <-> host, reply)
Establishes if the gateway/reader or host is online.
S1F1 W . * Header only
S1F2: ON-LINE DATA (host -> reader)
The host signals that it is online.
S1F2
    <L[2]
         <A[6]MDLN > 
         <A[6]SOFTREV > 
S1F2: ON-LINE (reader -> host)
The reader signals that it is online.
S1F2
     <L[2] 
          <A[6]MDLN > 
          <A[6]SOFTREV > 
>.
S1F15: REQUEST OFF_LINE (host ->reader, reply)
The reader is requested to change the communication status to offline.
The reader can only be set online again by using message S1F17 (or reset 
S2F19); all other messages are aborted by the SxF0 message.
S1F15 W. *Header only
S1F16: OFFLINE ACKNOWLEDGE (reader -> host)
Acknowledge.
S1F16
<B[1]OFLACK>.