Brooks Automation Inc. LF60C Manual De Usuario
Product Manual - RFID Reader LF60C SoliD
145
C h a p t e r 7
O p e r a t i o n
Reader to Host: S18F6
13:44:33 Incoming: ENQ ( 05 )
13:44:33 Outgoing: EOT ( 04 )
13:44:33 Incoming: Length byte ( 18 )
13:44:33 Incoming: Header ( 81 FF 12 06 80 01 00 00 00 40 )
13:44:33 Incoming: Data
13:44:33 Incoming: ENQ ( 05 )
13:44:33 Outgoing: EOT ( 04 )
13:44:33 Incoming: Length byte ( 18 )
13:44:33 Incoming: Header ( 81 FF 12 06 80 01 00 00 00 40 )
13:44:33 Incoming: Data
01 03
41 04 31 32 33 34 TARGETID "1234"
41 02 43 45
41 04 31 32 33 34 TARGETID "1234"
41 02 43 45
SSACK "CE"
41 00
DATA ""
13:44:33 Incoming: Checksum ( 04 78 )
13:44:33 Outgoing: ACK ( 06 )
The TARGETID in the S18F5 message does not correspond to the TARGETID in the
reader detecting the error. The reader therefore answers with communication
error "CE".
13:44:33 Outgoing: ACK ( 06 )
The TARGETID in the S18F5 message does not correspond to the TARGETID in the
reader detecting the error. The reader therefore answers with communication
error "CE".
The reader detects no tag
Host to Reader: S18F5
17:29:25 Outgoing: ENQ ( 05 )
17:29:25 Incoming: EOT ( 04 )
17:29:25 Outgoing: Length byte ( 1A )
17:29:25 Outgoing: Header ( 01 FF 92 05 80 01 00 00 00 43 )
17:29:25 Outgoing: Data
Host to Reader: S18F5
17:29:25 Outgoing: ENQ ( 05 )
17:29:25 Incoming: EOT ( 04 )
17:29:25 Outgoing: Length byte ( 1A )
17:29:25 Outgoing: Header ( 01 FF 92 05 80 01 00 00 00 43 )
17:29:25 Outgoing: Data
01 03
41 04 31 32 33 34 TARGETID "1234"
41 02 30 31
41 04 31 32 33 34 TARGETID "1234"
41 02 30 31
DATASEG "01"
A9 02 00 08
DATALENGTH 0x08
17:29:25 Outgoing: Checksum ( C5 02 )
17:29:25 Incoming: ACK ( 06 )
17:29:25 Incoming: ACK ( 06 )