Introduction 
v4.4 
Page 8 of 72 
2.4 
Restrictions and limitations 
The following restrictions and limitations must be considered: 
2.4.1 
AM systems versus RF systems 
It is not allowed to connect AM systems together with RF systems to the same Field Bus! 
Pins  3  and  6  on  BUS  A  and  BUS  B  of  the  AM  transceiver  and  receiver  boards  are  not 
interconnected.  They  are  used  for  communication  between  the  AM  transceiver  and  the 
AM receiver.  
On  RF  systems,  pins  3  and  6  are  used  for  synchronization  purposes  between  the  RF 
transmitter and the RF receiver, which is based on a completely different signal. 
Connecting  AM  and  RF  systems  to  the  same  Field  Bus  will  result  in  bad 
performance and synchronization and must be avoided! 
2.4.2 
Model restrictions 
The model restrictions are listed below: 
Lights only 
The  lights  only  model  does  not  contain  any  visitor  counters,  but  does  contain  LED 
indicators, which results in the following limitations: 
  No visitor counting, doorbell or auto antenna arrangement 
  No distinction between incoming and outgoing alarms 
 
If all of the above mentioned features are required then the  model with integrated visitor 
counters must be used. 
This manual  covers  the  complete  functionality  of  the  NEXUS  AM30.  Keeping  the  above 
mentioned  model  restrictions  in  mind,  sections  related  to  visitor  counting  and/or  alarm 
indication must be ignored when models without integrated visitor counters are used. 
2.4.3 
Software restrictions 
The AM systems can be tuned with Cross Po
int’s Device Explorer software. 
During  first-time  setup  of  Device  Explorer  you  are  required  to  specify  your  Cross  Point 
Cloud  credentials  in  order  to be  able  to use  the  Device  Explorer  software.  If  you  do  not 
have an account yet then contact 
your company’s administrator or Cross Point to obtain 
one. 
2.4.4 
Detection distances 
The  specified  detection  distances  are  maximum  values.  Dependent  of  environmental 
noise, these maximum values might not be achieved and aisle widths need to be reduced 
to  obtain  good  system  performance.  See  chapter  3  for  more  details  on  potential  noise 
sources and installation guidelines.