Safety instructions 
This  chapter  contains  information  on  safe  usage  of  the  NEXUS  AM  Deactivator.  Read 
this section carefully as it contains important safety guidelines. 
 
 
The NEXUS AM Deactivator generates high inducted voltage signals up 
to  400VDC.  If  the  housing  is  opened  without  disconnecting  the  mains 
power first, a high risk of electric shock is introduced.  
Therefore always disconnect the mains power first and wait at least 30 
seconds before opening the housing. 
 
1.  The  NEXUS  AM  Deactivator  must  be  mounted  in  such  a  way  that  it
’s  always 
possible to disconnect it from the mains power. 
2.  Always disconnect the mains power prior to opening the housing. 
3.  After the mains power has been disconnected, wait at least 30 seconds to allow 
the high voltage to discharge. 
4.  Only open the housing in case: 
a.  The mains voltage needs to be adjusted from 230VAC (default setting) to 
115VAC  or  vice  versa.  Use  switch  SW1  to  change  the  mains  voltage 
setting. 
b.  The  device  is  not  working  and  one  of  the  internal  fuses  needs  to  be 
checked or replaced. 
c.  The  device  is  not  working  and  the  antenna  connection  needs  to  be 
checked. 
d.  The battery for the internal clock needs to be replaced. 
5.  Do  not  place  magnetic  data  holders,  like  bank  cards,  credit  cards,  tapes,  etc., 
close to the NEXUS AM Deactivator, because the magnetic field will destroy the 
information  that  is  stored  on  the  magnetic  data  holder.  Keep  these  objects  at 
least 50cm away from the deactivator’s antenna while deactivation is active. 
3.3.1 
Serviceable parts 
The  following  parts  of  the  NEXUS  AM  Deactivator  are  serviceable  after  following  the 
above mentioned safety instructions: 
1.  External main fuse 160mA (230VAC) or 315mA (115VAC). Make sure to replace 
this fuse accordingly when the power input is switched! 
2.  Internal  mains  power  switch  for  230VAC  to  115VAC.  Make  sure  to  replace  the 
external fuse accordingly when the power input is switched! 
3.  Internal fuses F1 (T500mA) and F2 (T500mA) 
4.  Internal battery CR 1225 (3V lithium)