Cross Point b.v. CP321AMD Manual De Usuario

Descargar
Página de 26
NEXUS AM Deactivator 
 
 
 
 
 
Configuration 
v2.1 
Page 24 of 26 
The ‘Trigger on input method’ offers various methods as input, like Input low, Input high, 
Rising  edge,  Falling  edge  and  Rising  or  falling  edge.  This  offers  you  the  possibility  of 
ada
pting the deactivator’s input to the output of the external device. 
The  ‘Deactivator  enabled  for  deactivation  duration’  represents  the  deactivation  time 
window  in  which  the  deactivator  can  detect  and  deactivate  a  label  after  the  trigger  was 
activated  by  the  external  device.  When  this  time  has  passed,  the  external  device  must 
activate the trigger again to open up a new deactivation time window. The minimum value 
is 1 second and the maximum value is 254 seconds. The option ‘Infinite’ can be activated 
if an infinite deactivation window is required. 
The ‘Number of deactivations’ represents the maximum number of deactivations that are 
allowed  within  the  deactivation  time  window.  If  the  deactivation  time  window  is  set  to 
‘infinite’, the number of allowed deactivations will determine when the trigger needs to be 
activated again. 
7.7.1 
Tag detector 
The NEXUS AM deactivator can also be switched to a tag detector. In the detector mode, 
the  unit  only  detects  DR  labels  and  AM  hard  tags,  without  transmitting  deactivation 
pulses. In detector mode, the unit functions as a reminder unit. Please note that the unit 
can only be either a deactivator or a detector, not both at the same time.  
Tick  the  “Detect  only”  checkbox  to  switch  the  unit  to  detector  mode.  The  tag  detected 
notification must be configured to give the required buzzer and light signals when a tag is 
detected. The deactivation notifications (successful and failed) should be disabled.