710.0080 
SmarTire SmartWave External TPM Sensor Installation Guide 
 
Page 5 of 10 
7-
 
Install the metal stem on the valve by turning it slowly. Stop as soon as you heard 
a leak. Open the stem by rotating it back wards for about half-turn until leak stops. 
Do not touch the o-rings. 
8-
 
Assemble the transmitter unit on the stem by just pushing it in place. Make sure it 
is all the way down. 
9-
 
If there is enough room, reach the flat area on the stem and tight the unit using a 
9mm short handle spanner wrench to 1.5N.m (-0 / +0.5). If there is not enough 
room go to step 10. 
10-
 
Reach the hex at the back of the stem and use a 12mm wrench to tight it on the 
valve to 1.5N.m (-0 / +0.5). If there is not enough room go to step 11. 
11-
 
Assemble the nut. Make sure its Hex side is facing out. Hand tight the nut in 
place. 
12-
 
Use a 12mm wrench and tight the hex nut 1.5N.m (-0 / +0.5). Unit initiates a slow 
leak but it will stop leaking after couple turns. 
13-
 
You can adjust the transmitter after by rotating it to have maximum clearance 
against the brake assembly. 
14-
 
Adjust the pressure on all the tires. Refer to your vehicle’s manual for proper 
inflation pressures for each axle/tire position. 
15-
 
Make sure units are not leaking by applying some foam around them while the 
tires are pressurized.