UserManual.doc   15 
OPID Operation 
G4S Justice Services, Inc. recommends leaving the OPID on at all times 
while in the field. 
 
 
F
Figure 20: OPID
 
OPID Activation 
1.  The OPID is activated at the factory. 
OPID Power Down 
1.  The OPID can only be powered down at the factory or by taking it apart and removing the battery.  
 
PHMU Preparation 
PATROL SUITE RF has a PHMU that must be installed with the participant's PTX to monitor their activity 
with continuous signaling Radio Frequency (RF). To prepare the PHMU for installation, refer to the 
procedures/figures below:  
1.  Ensure that an active and valid OPID is present prior to beginning the Installation process. 
2.  Insert the PHMU Menu Key into the back of the PHMU and turn clockwise to the horizontal 
position. 
 Figure 21: Turning PHMU Menu Key 
3.  If installing a Landline PHMU, plug the phone cord into both the phone jack on the wall and one of 
the two available outlets on the back of the PHMU.  
NOTE: The second jack on the back of the PHMU can be used to connect the participant’s home 
telephone if no other phone outlets are available. 
WARNING: Connecting the PHMU to a digital phone system with an on hook voltage greater than 
55 volts (RJ-45 jacks connected to digital PBX lines) may cause permanent damage to the