Chamberlain Group Inc The 6597 Manual De Usuario

Descargar
Página de 19
20
SET OPEN
SET CLOSE
MOVE
GATE
OFF
5
10
60
180 MIN
MAX
(SECONDS)
OFF
ON
OPEN
CLOSE
ST
OP
INPUT POWER
BATT CHARGING
TIMER
GATE MOVING
BATT LOW
ACC PWR OVLD
DIAGNOSTIC
CODES
BIPART
DELAY
LEARN
TEST
BUTTONS
TIMER
TO CLOSE
REVERSAL
FORCE
STATUS:
OPEN
CLOSE
STOP
COMMON
“FIRE
DEPT.”
OPEN
EXIT
SHADOW
INTERRUPT
COMM LINK
B     A
-      +
-      +
EYES
EDGE
LOCK
N.O
.
COM
N.C
.
+      -
+      -
A
CCESSOR
PO
WER
ON           SW
.
EXP
.
BO
ARD
RESET
ENCODER
ID  IN  ALARM
SECURE / MANUAL
+      -
MOTOR
  +         -
DC   POWER
  +      -
   BATT
BATT  FUSE
30A  32V
1
6
3
4
XMITTER
NETWORK
PRESS &
RELEASE
TO BEGIN
SETUP
LIMIT
CLOSE
OPEN
DC POWER FUSE
30A
32V
CLASS 2 SUPPLY
24 VOLTS
60
180 MIN
MAX
NG
BATT LOW
ACC PWR OVLD
DIAG
C
SE
REVERSAL
FORCE
NETWORK
2
Outside
Pr
oper
ty
Inside
Pr
oper
ty
!
3
Outside
Pr
oper
ty
Inside
Pr
oper
ty
!
Outside
Pr
oper
ty
Inside
Pr
oper
ty
!
2
3
FORCE ADJUSTMENT + OBSTRUCTION TEST
ADJUSTMENT
OBSTRUCTION TEST
After any adjustments are made, test the operator: 
Open and close the gate with the test buttons, ensuring that the gate is 
stopping at the proper open and close limit positions.
Place a solid object between the open gate and a rigid structure. (Ensure that 
the gate, the solid object, and the rigid structure can withstand the forces 
generated during this obstruction test.)
Run the gate in the close direction. The gate should stop and reverse upon 
contact with the solid object. If the gate does not reverse off the solid object, 
reduce the force setting by turning the force control slightly counter-clockwise, 
as shown above in the “TO ADJUST THE FORCE” section.
Repeat the test for the open direction.
1
2
3
FORCE ADJUSTMENT
The operator is equipped with an automatic obstruction sensing feature. If the gate 
encounters an obstruction during motion, the operator will automatically reverse 
direction of the gate for a short time and then stop the gate. 
Based on the length and weight of the gate it may be necessary to make force 
adjustments. The force setting should be high enough that the gate will not reverse 
by itself nor cause nuisance interruptions, but low enough to prevent serious injury to 
a person. The force setting is the same for both the open and close gate directions. 
Perform the “Obstruction Test” after every force adjustment.
TO ADJUST THE FORCE
Open and close the gate with the test buttons. 
If the gate stops or reverses before reaching the fully open or closed position, 
increase the force by turning the force control slightly clockwise. 
If the gate cycles correctly limit-to-limit, reduce the force setting by turning the 
force control slightly counter-clockwise and cycle the gate again. If the gate 
now stops and reverses before reaching the fully open or closed position, 
increase the force by turning the force control slightly. Repeat as needed.
Perform the “Obstruction Test” after every force setting adjustment.
The basic installation is complete.
4
SET OPEN
SET CLOSE
MOVE
GATE
OFF
5
10
60
180 MIN
MAX
(SECONDS)
OFF
ON
OPEN
CLOSE
ST
OP
INPUT POWER
BATT CHARGING
TIMER
GATE MOVING
BATT LOW
ACC PWR OVLD
DIAGNOSTIC
CODES
BIPART
DELAY
LEARN
TEST
BUTTONS
TIMER
TO CLOSE
REVERSAL
FORCE
STATUS:
OPEN
CLOSE
STOP
COMMON
“FIRE
DEPT.”
OPEN
EXIT
SHADOW
INTERRUPT
COMM LINK
B     A
-      +
-      +
EYES
EDGE
LOCK
N.O
.
COM
N.C
.
+      -
+      -
A
CCESSOR
PO
WER
ON           SW
.
EXP
.
BO
ARD
RESET
ENCODER
ID  IN  ALARM
SECURE  / MANUAL
+      -
MOTOR
  +         -
DC   POWER
  +      -
   BATT
BATT  FUSE
30A  32V
1
6
3
4
XMITTER
NETWORK
PRESS &
RELEASE
TO BEGIN
SETUP
LIMIT
CLOSE
OPEN
DC POWER FUSE
30A
32V
CLASS 2 SUPPLY
24 VOLTS
MAX
OPEN
CLOSE
ST
OP
W
DIAGNOSTIC
TEST
BUTTONS
RSAL
RCE
XMITTER
NETWORK
1
SET OPEN
SET CLOSE
MOVE
GATE
OFF
5
10
60
180 MIN
MAX
(SECONDS)
OFF
ON
OPEN
CLOSE
ST
OP
INPUT POWER
BATT CHARGING
TIMER
GATE MOVING
BATT LOW
ACC PWR OVLD
DIAGNOSTIC
CODES
BIPART
DELAY
LEARN
TEST
BUTTONS
TIMER
TO CLOSE
REVERSAL
FORCE
STATUS:
OPEN
CLOSE
STOP
COMMON
“FIRE
DEPT.”
OPEN
EXIT
SHADOW
INTERRUPT
COMM LINK
B     A
-      +
-      +
EYES
EDGE
LOCK
N.O
.
COM
N.C
.
+      -
+      -
A
CCESSOR
PO
WER
ON           SW
.
EXP
.
BO
ARD
RESET
ENCODER
ID  IN  ALARM
SECURE  / MANUAL
+      -
MOTOR
  +         -
DC   POWER
  +      -
   BATT
BATT  FUSE
30A  32V
1
6
3
4
XMITTER
NETWORK
PRESS &
RELEASE
TO BEGIN
SETUP
LIMIT
CLOSE
OPEN
DC POWER FUSE
30A
32V
CLASS 2 SUPPLY
24 VOLTS
MAX
OPEN
CLOSE
ST
OP
W
DIAGNOSTIC
TEST
BUTTONS
RSAL
RCE
XMITTER
NETWORK
1
1
2
3